1VAD
MHC CLASS I H-2KB HEAVY CHAIN COMPLEXED WITH BETA-2 MICROGLOBULIN AND YEAST ALPHA-GLUCOSIDASE
Experimental procedure
| Detector technology | AREA DETECTOR |
| Detector | SIEMENS |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 138.010, 89.420, 45.920 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 6.000 - 2.500 |
| R-factor | 0.16 |
| Rwork | 0.160 |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.900 |
| Data reduction software | XENGEN |
| Phasing software | X-PLOR (3.1) |
| Refinement software | X-PLOR (3.1) |
Data quality characteristics
| Overall | |
| Rmerge | 0.068 |
| Number of reflections | 18677 |
| Completeness [%] | 91.5 |
| Redundancy | 1.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 |