Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1TI8

H7 Haemagglutinin

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2003-10-05
DetectorRIGAKU RAXIS IIC
Wavelength(s)1.54
Spacegroup nameH 3 2
Unit cell lengths118.200, 118.200, 298.700
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution20.000 - 3.000
R-factor0.23
Rwork0.230
R-free0.30000
Structure solution methodMOLECULAR REPLACEMENT
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0003.110
High resolution limit [Å]3.0003.000
Rmerge0.1020.376
Number of reflections16409
<I/σ(I)>15.55.4
Completeness [%]99.599.3
Redundancy4.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.229120% PEG3350 and 0.2M Sodium citrate dihydrate, pH 8.2, VAPOR DIFFUSION, HANGING DROP, temperature 291K

219869

PDB entries from 2024-05-15