1TH9

Effect of Shuttle Location and pH Environment on H+ Transfer in Human Carbonic Anhydrase II

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]293
Detector technologyIMAGE PLATE
DetectorRIGAKU RAXIS IV
Wavelength(s)1.54
Spacegroup nameP 1 21 1
Unit cell lengths42.616, 41.505, 72.872
Unit cell angles90.00, 104.63, 90.00
Refinement procedure
Resolution20.000 - 1.630
Rwork0.177
R-free0.21100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2cba
RMSD bond length0.005
RMSD bond angle1.351
Data scaling softwareSCALEPACK
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.660
High resolution limit [Å]1.6301.630
Number of reflections29130
Completeness [%]93.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP627750 mM Tris-Cl pH6.0, 2.5 M ammonium sulfate, VAPOR DIFFUSION, HANGING DROP, temperature 277K

219869

PDB entries from 2024-05-15