1TGG

RH3 DESIGNED RIGHT-HANDED COILED COIL TRIMER

Experimental procedure
Experimental methodMAD
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL1-5
Synchrotron siteSSRL
BeamlineBL1-5
Detector technologyAREA DETECTOR
Wavelength(s)1.4862, 1.4851, 1.3931
Spacegroup nameP 32
Unit cell lengths25.420, 25.420, 141.340
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution12.000 - 2.000
R-factor0.236
Rwork0.233
R-free0.26900
Structure solution methodMAD
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareMLPHARE
Refinement softwareX-PLOR (3.1)
Data quality characteristics
 Overall
Low resolution limit [Å]12.000
High resolution limit [Å]2.000
Number of reflections11956
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5298100mM Tris pH 8.5, 0.3M NaBr, 15mM NiCl2, 15% methyl pentanediol, 15% polyethylene glycol 4000, VAPOR DIFFUSION, HANGING DROP, temperature 298K

219869

PDB entries from 2024-05-15