1T4S
arginase-L-valine complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 19-ID |
| Synchrotron site | APS |
| Beamline | 19-ID |
| Temperature [K] | 110 |
| Detector technology | CCD |
| Collection date | 2001-02-11 |
| Detector | ADSC QUANTUM 4 |
| Wavelength(s) | 0.982 |
| Spacegroup name | P 32 |
| Unit cell lengths | 87.800, 87.800, 110.500 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 28.740 - 2.800 |
| R-factor | 0.258 |
| Rwork | 0.258 |
| R-free | 0.29200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.400 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | CNS (1.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.900 |
| High resolution limit [Å] | 2.800 | 2.800 |
| Number of reflections | 26074 | |
| Completeness [%] | 99.6 | 100 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 277 | bicine, PEG8000, L-valine, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |