1T01
Vinculin complexed with the VBS1 helix from talin
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID14-4 |
| Synchrotron site | ESRF |
| Beamline | ID14-4 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Detector | ADSC QUANTUM 4 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 51.645, 71.421, 96.093 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | ? - 2.060 |
| Rwork | 0.230 |
| R-free | 0.30300 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.200 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | AMoRE |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.070 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Number of reflections | 24132 | |
| <I/σ(I)> | 2.509 | |
| Completeness [%] | 98.4 | 90.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | 6.5 | 293 | 30%PEG 5000, 0.1M MES, 0.2M Ammonium Sulphate, pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K, pH 6.50 |