1SE2
STAPHYLOCOCCAL ENTEROTOXIN C2, MONOCLINIC FORM
Experimental procedure
Collection date | 1994 |
Detector | SIEMENS |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 43.430, 69.920, 42.220 |
Unit cell angles | 90.00, 90.10, 90.00 |
Refinement procedure
Resolution | 8.000 - 2.700 |
R-factor | 0.196 |
Rwork | 0.196 |
R-free | 0.32000 |
RMSD bond length | 0.016 |
RMSD bond angle | 25.800 * |
Data reduction software | XGEN |
Phasing software | X-PLOR |
Refinement software | X-PLOR |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 20.000 |
High resolution limit [Å] | 2.700 |
Rmerge | 0.053 |
Total number of observations | 16415 * |
Number of reflections | 7124 |
Completeness [%] | 85.0 |
Redundancy | 2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | unknown * | 7 * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | reservoir | PEG6000 | 20 (%) | |
2 | 1 | reservoir | HEPES | 100 (mM) |