1RYO
Human serum transferrin, N-lobe bound with oxalate
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CHESS BEAMLINE A1 |
| Synchrotron site | CHESS |
| Beamline | A1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2002-03-27 |
| Detector | ADSC QUANTUM 4 |
| Wavelength(s) | 0.935 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 44.092, 57.252, 135.988 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 30.000 - 1.200 |
| Rwork | 0.221 |
| R-free | 0.23500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1a8e |
| RMSD bond length | 0.004 |
| RMSD bond angle | 1.300 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 1.240 |
| High resolution limit [Å] | 1.200 | 1.200 |
| Number of reflections | 101890 | |
| Completeness [%] | 94.0 | 86.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.7 | 293 | 0.2M K-Acetate, 10mM KCl, 20% PEG 3350, pH 7.7, VAPOR DIFFUSION, SITTING DROP, temperature 293K |