1RVX
1934 H1 Hemagglutinin in complex with LSTA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-1 |
Synchrotron site | ESRF |
Beamline | ID14-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2002-09-26 |
Detector | ADSC QUANTUM 4 |
Wavelength(s) | 0.933 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 227.878, 131.344, 174.708 |
Unit cell angles | 90.00, 110.09, 90.00 |
Refinement procedure
Resolution | 20.000 - 2.200 |
R-factor | 0.227 |
Rwork | 0.227 |
R-free | 0.26000 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ru7 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | CNS (1.0) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.280 |
High resolution limit [Å] | 2.200 | 2.200 |
Rmerge | 0.071 | 0.528 |
Number of reflections | 216839 | |
<I/σ(I)> | 17.8 | 2 |
Completeness [%] | 88.8 | 50.6 |
Redundancy | 9.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 291 | PEG3350, TrisHCl, KSCN, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 291K |