1RVW
R STATE HUMAN HEMOGLOBIN [ALPHA V96W], CARBONMONOXY
Experimental procedure
Source type | ROTATING ANODE |
Source details | RIGAKU RUH2R |
Temperature [K] | 293 |
Detector technology | AREA DETECTOR |
Collection date | 1995-02 |
Detector | SIEMENS |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 54.282, 54.282, 194.122 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 25.000 - 2.500 |
R-factor | 0.167 |
Rwork | 0.167 |
Structure solution method | DIFFERENCE FOURIER |
Starting model (for MR) | 1hho |
RMSD bond length | 0.008 |
RMSD bond angle | 1.300 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | X-PLOR (3.851) |
Refinement software | X-PLOR (3.851) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 25.000 | 2.610 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.065 | |
Number of reflections | 9340 | 993 * |
Completeness [%] | 86.7 | 75.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Batch method * | Perutz, M.F., (1968) J.Crystal Growth, 2, 54. * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | 1 | 4 (M) | ||
2 | 1 | 1 | 2 (M) | ||
3 | 1 | 1 | 2 (M) |