Nuclear Transport Factor 2 (NTF2) W7A mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsELETTRA BEAMLINE 5.2R
Synchrotron siteELETTRA
Beamline5.2R
Temperature [K]100
Detector technologyIMAGE PLATE
DetectorMARRESEARCH
Spacegroup nameP 1 21 1
Unit cell lengths64.652, 75.407, 64.543
Unit cell angles90.00, 115.00, 90.00
Refinement procedure
Resolution6.000 - 2.500
Rwork0.208
R-free0.24000
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1oun
RMSD bond length0.012
RMSD bond angle0.033
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareAMoRE
Refinement softwareREFMAC
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]22.7002.640
High resolution limit [Å]2.5002.500
Rmerge0.0820.194
Total number of observations65817

*

Number of reflections18928
<I/σ(I)>6.13.5
Completeness [%]97.491.8
Redundancy2.52.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

7.518

*

pH 7.50
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein1.5 (mg/ml)
21reservoirammonium sulfate1.32 (M)
31reservoirisopropanol3 (%(v/v))
41reservoirTris-HCl100 (mM)