Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1QG7

STROMA CELL-DERIVED FACTOR-1ALPHA (SDF-1ALPHA)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]297
Detector technologyIMAGE PLATE
DetectorRIGAKU
Spacegroup nameP 21 21 21
Unit cell lengths38.900, 51.200, 66.500
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution60.000 - 2.000
Rwork0.189
R-free0.25800
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.500
Data reduction softwarePROCESS
Data scaling softwarePROCESS
Refinement softwareX-PLOR (3.851)
Data quality characteristics
 Overall
Low resolution limit [Å]60.000
High resolution limit [Å]2.000
Rmerge0.056
Number of reflections9133
<I/σ(I)>16.2
Completeness [%]95.8
Redundancy3.98
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
17pH 7.0

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon