1Q1P
E-Cadherin activation
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | ELLIOTT GX-21 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2002-12-25 |
| Detector | MARRESEARCH |
| Wavelength(s) | 1.5418 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 129.204, 48.601, 58.669 |
| Unit cell angles | 90.00, 113.93, 90.00 |
Refinement procedure
| Resolution | 20.000 - 3.200 |
| R-factor | 0.26155 |
| Rwork | 0.259 |
| R-free | 0.30484 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1FF5.pdb |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.877 |
| Data reduction software | MOSFLM |
| Data scaling software | CCP4 ((SCALA)) |
| Phasing software | AMoRE |
| Refinement software | REFMAC (5.0) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 37.470 |
| High resolution limit [Å] | 3.180 |
| Number of reflections | 5324 |
| <I/σ(I)> | 8.3 |
| Completeness [%] | 99.8 |
| Redundancy | 3.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 |