1OUU
CARBONMONOXY TROUT HEMOGLOBIN I
Experimental procedure
| Detector technology | AREA DETECTOR |
| Detector | SIEMENS |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 65.200, 79.800, 122.900 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 8.000 - 2.500 |
| R-factor | 0.162 * |
| Rwork | 0.162 |
| R-free | 0.28600 |
| RMSD bond length | 0.014 |
| RMSD bond angle | 0.033 |
| Data reduction software | XDS |
| Refinement software | PROLSQ |
Data quality characteristics
| Overall | |
| Rmerge | 0.065 |
| Number of reflections | 22054 |
| Completeness [%] | 74.1 |
| Redundancy | 1.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion, hanging drop * | 8 * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | PEG4000 | 15 (%(w/v)) | |
| 2 | 1 | drop | Tris-HCl | 50 (mM) | |
| 3 | 1 | drop | protein | 10 (mg/ml) |