1NOL
OXYGENATED HEMOCYANIN (SUBUNIT TYPE II)
Experimental procedure
| Temperature [K] | 293 |
| Detector technology | DIFFRACTOMETER |
| Detector | ENRAF-NONIUS FAST |
| Wavelength(s) | 1.5418 |
| Spacegroup name | R 3 2 |
| Unit cell lengths | 117.002, 117.002, 117.002 |
| Unit cell angles | 60.02, 60.02, 60.02 |
Refinement procedure
| Resolution | 8.000 - 2.400 |
| R-factor | 0.181 |
| Rwork | 0.181 |
| RMSD bond length | 0.018 |
| RMSD bond angle | 3.400 |
| Data reduction software | MADNES |
| Phasing software | X-PLOR (2.1) |
| Refinement software | X-PLOR (2.1) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 33.800 |
| High resolution limit [Å] | 2.400 |
| Rmerge | 0.052 |
| Number of reflections | 24861 |
| Completeness [%] | 83.7 |
| Redundancy | 5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | unknown * |