Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1NFT

OVOTRANSFERRIN, N-TERMINAL LOBE, IRON LOADED OPEN FORM

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsMACSCIENCE M18X
Temperature [K]293
Detector technologyAREA DETECTOR
Collection date1997-10-15
DetectorSIEMENS
Spacegroup nameP 63 2 2
Unit cell lengths125.290, 125.290, 87.530
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution7.000 - 2.100
R-factor0.189
Rwork0.189
R-free0.25600
Structure solution methodOTHER
RMSD bond length0.014
RMSD bond angle25.000

*

Data reduction softwareSAINT
Data scaling softwareSAINT
Phasing softwareX-PLOR
Refinement softwareX-PLOR (3.1)
Data quality characteristics
 Overall
Low resolution limit [Å]30.000
High resolution limit [Å]2.090
Rmerge0.079

*

Total number of observations188024

*

Number of reflections24284

*

Completeness [%]100.0
Redundancy5.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

6

*

20

*

pH 7.5
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein44.4 (mg/ml)
21dropBis Tris-HCl0.05 (M)
31reservoirBis-Tris0.05 (M)
41reservoirammonium sulfate52 (%)

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon