Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1NDU

Bacillus lentus subtilisin variant S101G/V104N

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Wavelength(s)1.5418
Spacegroup nameP 21 21 21
Unit cell lengths47.750, 62.500, 75.600
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution10.000 - 1.600
R-factor0.173
Rwork0.173
R-free0.22200
Structure solution methodMOLECULAR REPLACEMENT
Phasing softwareCNX
Refinement softwareCNX
Data quality characteristics
 Overall
Low resolution limit [Å]10.000
High resolution limit [Å]1.600
Number of reflections25257
Completeness [%]89.0
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

219869

PDB entries from 2024-05-15