1MMQ
MATRILYSIN COMPLEXED WITH HYDROXAMATE INHIBITOR
Experimental procedure
Detector technology | IMAGE PLATE |
Collection date | 1993-10-05 |
Detector | MARRESEARCH |
Wavelength(s) | 1.5418 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 61.900, 61.900, 88.000 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 6.000 - 1.900 |
R-factor | 0.179 |
Rwork | 0.179 |
RMSD bond length | 0.013 |
RMSD bond angle | 2.730 |
Data reduction software | MOSFLM (V. 5.1.2) |
Phasing software | X-PLOR (3.1) |
Refinement software | X-PLOR (3.1) |
Data quality characteristics
Overall | |
High resolution limit [Å] | 1.900 * |
Rmerge | 0.120 |
Total number of observations | 83992 * |
Number of reflections | 15546 |
Completeness [%] | 92.7 |
Redundancy | 5.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion, hanging drop * | 7.5 * | 17-25 * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | protein | 10 (mg/ml) | |
2 | 1 | drop | inhibitor | 1.2 (mM) | |
3 | 1 | drop | DMSO | 2.5 (%) | |
4 | 1 | reservoir | 0.2 (M) | ||
5 | 1 | reservoir | HEPES | 0.1 (M) | |
6 | 1 | reservoir | 2-propanol | 30 (%) |