1LUQ
Full Matrix Error Analysis of Streptavidin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL9-1 |
Synchrotron site | SSRL |
Beamline | BL9-1 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 1999-01-01 |
Detector | MARRESEARCH |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 46.027, 93.540, 104.170 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 14.000 - 0.960 |
Rwork | 0.139 |
R-free | 0.16450 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1df8 |
RMSD bond length | 0.019 |
RMSD bond angle | 0.036 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | SHELXS |
Refinement software | SHELXL-97 |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 14.000 | 0.970 |
High resolution limit [Å] | 0.960 | 0.960 |
Rmerge | 0.065 | 0.602 |
Number of reflections | 135985 | |
Completeness [%] | 96.4 | 45 |
Redundancy | 8.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.5 | 293 | ammonium sulfate, sodium acetate, biotin, pH 4.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K |