1LES

LENTIL LECTIN COMPLEXED WITH SUCROSE

Experimental procedure
Detector technologyDIFFRACTOMETER
Collection date1994-06-24
DetectorENRAF-NONIUS FAST
Wavelength(s)1.5418
Spacegroup nameP 1 21 1
Unit cell lengths50.030, 124.800, 50.020
Unit cell angles90.00, 111.80, 90.00
Refinement procedure
Resolution6.000 - 1.900
R-factor0.188
Rwork0.188
RMSD bond length0.020
RMSD bond angle28.840

*

Data reduction softwareMADNES
Phasing softwareX-PLOR (3.1)
Refinement softwareX-PLOR (3.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]15.000
High resolution limit [Å]1.900

*

1.900

*

Rmerge0.0730.295

*

Total number of observations114331

*

Number of reflections43108
Completeness [%]69.975.1

*

Redundancy2.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

6.5pH 6.5
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein 6.25 (mg/ml)
21dropcacodylate50 (mM)
31dropsucrose25 (mM)
41dropMPD20 (%(v/v))
51reservoirMPD40 (%(v/v))
61reservoircacodylate100 (mM)

219869