1KOP
NEISSERIA GONORRHOEAE CARBONIC ANHYDRASE
Experimental procedure
Source type | ROTATING ANODE |
Source details | ENRAF-NONIUS FR591 |
Temperature [K] | 293 |
Detector technology | IMAGE PLATE |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 47.230, 74.940, 62.380 |
Unit cell angles | 90.00, 93.87, 90.00 |
Refinement procedure
Resolution | 5.000 - 1.900 |
R-factor | 0.208 * |
Rwork | 0.206 |
R-free | 0.28500 * |
Structure solution method | MR |
RMSD bond length | 0.007 * |
RMSD bond angle | 1.240 * |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | X-PLOR (3.851) |
Refinement software | X-PLOR (3.851) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 28.000 |
High resolution limit [Å] | 1.900 |
Rmerge | 0.072 |
Number of reflections | 28517 |
Completeness [%] | 83.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7.8 | 6% PEG 3,350; 50MM TRIS; 0.1 M LI2SO4;2.2 MM BME; 2.2 MM NAN3; 10% DMSO, pH 7.8 |