1JYC
CONCANAVALIN A/15-mer PEPTIDE COMPLEX
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Detector technology | IMAGE PLATE |
Detector | MARRESEARCH |
Wavelength(s) | 1.54178 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 103.113, 118.547, 254.994 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 10.000 - 2.750 |
Rwork | 0.195 |
R-free | 0.24000 |
Starting model (for MR) | 5cna |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | CNS (0.5) |
Data quality characteristics
Overall | |
High resolution limit [Å] | 2.750 |
Rmerge | 0.100 |
<I/σ(I)> | 6.2 |
Completeness [%] | 78.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |