1JRE
DNA PROTECTION AND BINDING BY E. COLI DPS PROTEIN
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | MACSCIENCE |
Temperature [K] | 95 |
Detector technology | IMAGE PLATE |
Collection date | 1998-07-03 |
Detector | MAC Science DIP-2030 |
Wavelength(s) | 1.5418 |
Spacegroup name | P 32 |
Unit cell lengths | 90.585, 90.585, 226.507 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 45.920 - 2.650 |
Rwork | 0.229 |
R-free | 0.26400 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1f33 |
RMSD bond length | 0.007 |
RMSD bond angle | 1.200 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | CNS (1.0) |
Refinement software | CNS (1.0) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 500.000 | 2.670 |
High resolution limit [Å] | 2.620 | 2.620 |
Rmerge | 0.041 | 0.220 |
Number of reflections | 61832 | |
<I/σ(I)> | 16.5 | |
Completeness [%] | 98.7 | 91.3 |
Redundancy | 3.33 | 1.46 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.1 | 298 | 10MM MOPS, 100MM KCL, 10% GLYCEROL + 100MM TRISHCL, 100MM KCL, 10% GLYCEROL, 11% PEG 8000, AND 5MM DTT, pH 8.10, VAPOR DIFFUSION, HANGING DROP, temperature 298K |