1IQJ
Human coagulation factor Xa in complex with M55124
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 1999-04-29 |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 72.000, 78.160, 56.750 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 8.000 - 3.000 |
Rwork | 0.189 |
R-free | 0.29300 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.300 |
Phasing software | GLRF |
Refinement software | CNX (2000) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 3.100 | |
High resolution limit [Å] | 3.000 | 3.000 |
Rmerge | 0.059 | 0.077 |
Number of reflections | 5604 | |
Completeness [%] | 82.2 | 65.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.2 | 293 | PEG1500, calcium chloride, M55124, tris-HCl, pH 7.20, VAPOR DIFFUSION, SITTING DROP, temperature 293K |