1IOE
Human coagulation factor Xa in complex with M55532
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 1998-12-18 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 72.700, 78.170, 56.040 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 8.000 - 2.900 |
| Rwork | 0.201 |
| R-free | 0.29500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.400 |
| Phasing software | GLRF |
| Refinement software | CNX (2000) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 20.000 |
| High resolution limit [Å] | 2.900 |
| Rmerge | 0.082 |
| Number of reflections | 5790 |
| Completeness [%] | 81.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.2 | 293 | PEG1500, CALCIUM CHLORIDE, M55532,TRIS-HCL, pH 7.20, VAPOR DIFFUSION, SITTING DROP, temperature 293.0K |