Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SEALED TUBE |
| Source details | OTHER |
| Detector technology | DIFFRACTOMETER |
| Collection date | 1991-01-01 |
| Detector | ENRAF-NONIUS CAD4 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 53.300, 61.500, 75.100 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 10.000 - 1.800 |
| R-factor | 0.148 |
| RMSD bond length | 0.014 |
| RMSD bond angle | 2.800 |
| Data reduction software | CAD4 |
| Data scaling software | CAD4 |
| Refinement software | PROLSQ |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 10.000 |
| High resolution limit [Å] | 1.800 |
| Rmerge | 0.069 |
| Number of reflections | 16480 |
| Completeness [%] | 73.0 |
| Redundancy | 1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion * | 5.9 | drop consists of equal amounts of protein and reservoir solutions * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | protein | 6 (mg/ml) | |
| 2 | 1 | drop | sodium acetate | 50 (mM) | |
| 3 | 1 | drop | calcium chloride | 10 (mM) | |
| 4 | 1 | reservoir | ammonium sulfate | 29 (%(w/v)sat) |