Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SEALED TUBE |
Source details | OTHER |
Detector technology | DIFFRACTOMETER |
Collection date | 1991-01-01 |
Detector | ENRAF-NONIUS CAD4 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 53.300, 61.500, 75.100 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 10.000 - 1.800 |
R-factor | 0.148 |
RMSD bond length | 0.014 |
RMSD bond angle | 2.800 |
Data reduction software | CAD4 |
Data scaling software | CAD4 |
Refinement software | PROLSQ |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 10.000 |
High resolution limit [Å] | 1.800 |
Rmerge | 0.069 |
Number of reflections | 16480 |
Completeness [%] | 73.0 |
Redundancy | 1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion * | 5.9 | drop consists of equal amounts of protein and reservoir solutions * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | protein | 6 (mg/ml) | |
2 | 1 | drop | sodium acetate | 50 (mM) | |
3 | 1 | drop | calcium chloride | 10 (mM) | |
4 | 1 | reservoir | ammonium sulfate | 29 (%(w/v)sat) |