Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1HVE

STRUCTURAL AND ELECTROPHYSIOLOGICAL ANALYSIS OF ANNEXIN V MUTANTS. MUTAGENESIS OF HUMAN ANNEXIN V, AN IN VITRO VOLTAGE-GATED CALCIUM CHANNEL, PROVIDES INFORMATION ABOUT THE STRUCTURAL FEATURES OF THE ION PATHWAY, THE VOLTAGE SENSOR AND THE ION SELECTIVITY FILTER

Experimental procedure
Spacegroup nameH 3
Unit cell lengths99.600, 99.600, 96.700
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution8.000

*

- 2.300
R-factor0.164
Rwork0.164
RMSD bond length0.012
RMSD bond angle2.820
Phasing softwareX-PLOR
Refinement softwareX-PLOR
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]9999.000

*

High resolution limit [Å]2.2002.200

*

Rmerge0.097

*

Total number of observations63832

*

Number of reflections13835
Completeness [%]76.235.1

*

Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion

*

8.5

*

Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropMOPS3 (mM)
21dropprotein9 (mg/ml)
31drop20 (mM)
41reservoirammonium sulfate2.1 (M)
51reservoirTris-chloride0.1 (M)

220113

PDB entries from 2024-05-22

PDB statisticsPDBj update infoContact PDBjnumon