Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1GEZ

BURIED POLAR MUTANT HUMAN LYSOZYME

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU300
Temperature [K]283
Detector technologyIMAGE PLATE
Collection date2000-09-19
DetectorRIGAKU RAXIS IV
Wavelength(s)1.5418
Spacegroup nameP 21 21 21
Unit cell lengths56.240, 61.230, 32.880
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution8.000 - 1.800
Rwork0.167
Phasing softwareX-PLOR
Refinement softwareX-PLOR (3.1)
Data quality characteristics
 Overall
High resolution limit [Å]1.800
Rmerge0.043
Total number of observations34540

*

Number of reflections10750
Completeness [%]97.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.510

*

drop contains protein and reservoir solution in a 1:1 ratio

*

Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein10 (mg/ml)
21reservoir2.5 (M)
31reservoiracetate20 (mM)

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon