1FUO
FUMARASE C WITH BOUND CITRATE
Experimental procedure
| Temperature [K] | 294 |
| Detector technology | AREA DETECTOR |
| Collection date | 1995 |
| Detector | SIEMENS-NICOLET X100 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 104.000, 219.900, 86.700 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 8.000 - 1.980 |
| R-factor | 0.165 |
| Rwork | 0.165 |
| R-free | 0.20600 |
| RMSD bond length | 0.007 |
| RMSD bond angle | 21.050 * |
| Data reduction software | XENGEN |
| Phasing software | X-PLOR |
| Refinement software | X-PLOR |
Data quality characteristics
| Overall | |
| High resolution limit [Å] | 1.980 * |
| Rmerge | 0.062 * |
| Number of reflections | 69760 * |
| Completeness [%] | 93.5 * |
| Redundancy | 4.45 * |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion, hanging drop * | 6 * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | reservoir | citrate | 300 (mM) | |
| 2 | 1 | reservoir | PEG4000 | 14 (%) |