1FTS
SIGNAL RECOGNITION PARTICLE RECEPTOR FROM E. COLI
Experimental procedure
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE BM14 |
| Synchrotron site | ESRF |
| Beamline | BM14 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 1996-06 |
| Detector | MARRESEARCH |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 32.559, 79.577, 59.206 |
| Unit cell angles | 90.00, 94.45, 90.00 |
Refinement procedure
| Resolution | 7.500 - 2.200 |
| R-factor | 0.222 |
| Rwork | 0.222 |
| R-free | 0.28000 |
| Structure solution method | MIRAS |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.560 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | PHASES |
| Refinement software | X-PLOR (3.4) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 30.000 |
| High resolution limit [Å] | 2.200 |
| Rmerge | 0.038 * |
| Number of reflections | 15365 |
| <I/σ(I)> | 15 |
| Completeness [%] | 98.0 |
| Redundancy | 4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion, hanging drop * | 6 | 4 * | VAPOR DIFFUSION, pH 6.0, vapor diffusion |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | protein | 5 (mg/ml) | |
| 2 | 1 | reservoir | bis-Tris | 50 (mM) | |
| 3 | 1 | reservoir | 200 (mM) | ||
| 4 | 1 | reservoir | PEG8000 | 18 (%) |