1DM0

SHIGA TOXIN

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPHOTON FACTORY BEAMLINE BL-6A
Synchrotron sitePhoton Factory
BeamlineBL-6A
Temperature [K]277
Detector technologyDIFFRACTOMETER
Collection date1992-10-23
DetectorWEISSENBERG
Spacegroup nameP 21 21 21
Unit cell lengths133.050, 147.460, 83.040
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution10.000 - 2.500
R-factor0.206
Rwork0.206
RMSD bond length0.011
RMSD bond angle20.400

*

Data reduction softwareBIOMOL
Data scaling softwareWEIS
Phasing softwareMLPHARE
Refinement softwareTNT
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]10.0002.670
High resolution limit [Å]2.5002.500
Number of reflections47612
Completeness [%]83.153.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5294Kozlov, Y.Z., (1993) J. Mol. Biol., 232, 704.

*