Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | SIEMENS |
Temperature [K] | 120 |
Detector technology | AREA DETECTOR |
Collection date | 1997-12-01 |
Detector | SIEMENS |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 52.340, 82.820, 166.740 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 5.000 - 2.270 |
R-factor | 0.168 |
Rwork | 0.168 |
R-free | 0.22700 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1fbe |
RMSD bond length | 0.007 |
RMSD bond angle | 24.160 * |
Data reduction software | XENGEN |
Data scaling software | XENGEN |
Phasing software | CNS (0.5) |
Refinement software | CNS (0.5) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 99.000 | 2.400 |
High resolution limit [Å] | 2.270 | 2.270 |
Rmerge | 0.055 | |
Number of reflections | 15519 | |
Completeness [%] | 90.0 | 56 |
Redundancy | 4.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion, hanging drop * | 7.4 | 37 * | drop consists of equal volume of protein and reservoir solutions * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | protein | 10 (mg/ml) | |
2 | 1 | drop | Tris-malonate | 2.5 (mM) | |
3 | 1 | drop | 10 (mM) | ||
4 | 1 | drop | 5 (mM) | ||
5 | 1 | drop | F6P | 5 (mM) | |
6 | 1 | reservoir | Tris-malonate | 2.5 (mM) | |
7 | 1 | reservoir | PEG3350 | 6 (%(w/v)) |