1CH3

RECOMBINANT SPERM WHALE MYOGLOBIN L89W MUTANT (MET)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsSIEMENS
Temperature [K]295
Detector technologyIMAGE PLATE
Collection date1997-03-08
DetectorRIGAKU RAXIS IIC
Spacegroup nameP 6
Unit cell lengths91.723, 91.723, 46.021
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution5.000 - 2.000
R-factor0.1482
R-free0.19200

*

Structure solution methodOTHER
Starting model (for MR)1MBW
RMSD bond length0.009

*

RMSD bond angle2.000

*

Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareSHELXS
Refinement softwareSHELXL-97
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]2.000
Rmerge0.069
Total number of observations76505

*

Number of reflections15027

*

Completeness [%]99.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

92.6-3.0 M (NH4)2SO4, 20 MM TRIS,1 MM EDTA, PH 9.0
Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropprotein20 (mg/ml)
21dropammonium sulfate2.4-3.0 (M)
31dropTris-HCl20 (mM)
41dropEDTA1 (mM)
51reservoirammonium sulfate2.4-3.0 (M)