1BLN
ANTI-P-GLYCOPROTEIN FAB MRK-16
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 293 |
| Detector technology | AREA DETECTOR |
| Detector | SDMS |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 54.490, 67.774, 117.186 |
| Unit cell angles | 90.00, 97.61, 90.00 |
Refinement procedure
| Resolution | 8.000 - 2.800 |
| R-factor | 0.209 |
| Rwork | 0.209 |
| R-free | 0.28700 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1mcp |
| RMSD bond length | 0.006 |
| RMSD bond angle | 27.200 * |
| Phasing software | X-PLOR |
| Refinement software | X-PLOR (3.8) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 3.000 |
| High resolution limit [Å] | 2.800 | 2.800 |
| Rmerge | 0.114 * | 0.220 * |
| Total number of observations | 56513 * | |
| Number of reflections | 18167 | 3111 * |
| <I/σ(I)> | 9.7 | 2.1 |
| Completeness [%] | 86.0 | 75 |
| Redundancy | 4 | 1.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | other * | 4 | Vasudevan, S., (1994) J. Mol. Biol., 241, 736. * |