1BEP
EFFECT OF UNNATURAL HEME SUBSTITUTION ON KINETICS OF ELECTRON TRANSFER IN CYTOCHROME C PEROXIDASE
Experimental procedure
| Source type | ROTATING ANODE |
| Source details | RIGAKU RUH2R |
| Temperature [K] | 273 |
| Detector technology | AREA DETECTOR |
| Collection date | 1997-06 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 105.120, 74.306, 45.364 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 20.000 - 2.200 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 2.109 |
| Refinement software | TNT (1) |
Data quality characteristics
| Overall | Outer shell | |
| High resolution limit [Å] | 2.200 | 2.200 |
| Number of reflections | 22700 | |
| <I/σ(I)> | 2.77 | |
| Completeness [%] | 95.0 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | 6 | 30% MPD; 50 MM POTASSIUM PHOSPHATE, PH 6.0 |