1AB1
SI FORM CRAMBIN
Experimental procedure
| Source type | ROTATING ANODE |
| Source details | RIGAKU RUH2R |
| Temperature [K] | 150 |
| Detector technology | IMAGE PLATE |
| Collection date | 1992-10 |
| Detector | RIGAKU |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 40.759, 18.404, 22.273 |
| Unit cell angles | 90.00, 90.70, 90.00 |
Refinement procedure
| Resolution | 10.000 - 0.890 |
| R-factor | 0.147 |
| Structure solution method | ALREADY SOLVED |
| RMSD bond length | 0.014 |
| RMSD bond angle | 0.033 |
| Data reduction software | TEXSAN |
| Data scaling software | TEXSAN |
| Refinement software | PROLSQ |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 17.670 | 0.897 |
| High resolution limit [Å] | 0.890 | 0.890 |
| Rmerge | 0.040 | 0.100 |
| Number of reflections | 23165 | |
| <I/σ(I)> | 8.3 | 3.2 |
| Completeness [%] | 88.8 | 74.96 |
| Redundancy | 1 | 0.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion * | 7 | 20 * | Teeter, M.M., (1979) J. Mol. Biol., 127, 219. * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | protein solution | 30 (mg/ml) | |
| 2 | 1 | drop | ethanol | 80 (%(v/v)) | |
| 3 | 1 | reservoir | ethanol | 50 (%) |