1AAC
AMICYANIN OXIDIZED, 1.31 ANGSTROMS
Experimental procedure
Detector technology | AREA DETECTOR |
Collection date | 1991-06-20 |
Detector | XUONG-HAMLIN MULTIWIRE |
Wavelength(s) | 1.5418 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 28.950, 56.540, 27.550 |
Unit cell angles | 90.00, 96.38, 90.00 |
Refinement procedure
Resolution | 8.000 - 1.310 |
R-factor | 0.155 |
Rwork | 0.155 |
RMSD bond length | 0.010 |
RMSD bond angle | 2.520 |
Data reduction software | SDMS |
Phasing software | X-PLOR (2.1) |
Refinement software | X-PLOR (2.1) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 20.160 |
High resolution limit [Å] | 1.310 |
Rmerge | 0.050 |
Total number of observations | 199399 * |
Number of reflections | 21219 |
Completeness [%] | 99.0 |
Redundancy | 5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | reservoir | phosphate | 3.0 (M) | |
2 | 1 | reservoir | ammonium sulfate |