Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID30B |
| Synchrotron site | ESRF |
| Beamline | ID30B |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-09-07 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.873129 |
| Spacegroup name | P 2 21 21 |
| Unit cell lengths | 33.158, 85.766, 115.625 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 47.940 - 2.050 |
| Rwork | 0.209 |
| R-free | 0.25410 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21.None-5190) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 47.940 | 2.170 |
| High resolution limit [Å] | 2.050 | 2.050 |
| Number of reflections | 21529 | 3386 |
| <I/σ(I)> | 4.9 | 1.1 |
| Completeness [%] | 99.7 | |
| Redundancy | 7.3 | |
| CC(1/2) | 0.987 | 0.708 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.4 | 293 | 0.1 M Bis-Tris-Propane, pH 6.4, 0.2 M K-thiocyanate, 8% PEG 3350 |