Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

9PAI

CLEAVED SUBSTRATE VARIANT OF PLASMINOGEN ACTIVATOR INHIBITOR-1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsSIEMENS
Temperature [K]287
Detector technologyAREA DETECTOR
Collection date1994-09-15
DetectorSIEMENS
Spacegroup nameC 1 2 1
Unit cell lengths151.860, 47.520, 62.730
Unit cell angles90.00, 113.95, 90.00
Refinement procedure
Resolution10.000 - 2.700
Rwork0.181
R-free0.29500
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)LATENT PAI-1
RMSD bond length0.006
RMSD bond angle1.300
Data reduction softwareSAINT
Data scaling softwareSAINT
Phasing softwareX-PLOR
Refinement softwareX-PLOR (3.843)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.0002.800
High resolution limit [Å]2.7002.700
Rmerge0.090
Number of reflections9914
<I/σ(I)>9.921.6
Completeness [%]71.061
Redundancy2.51.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
18.519% (W/V) PEG 4000, 100 MM TRIS PH 8.5

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon