9F4W

UP1 in complex with Z54508609

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-29
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.91587
Spacegroup nameP 1 21 1
Unit cell lengths37.955, 43.807, 56.143
Unit cell angles90.00, 94.46, 90.00
Refinement procedure
Resolution37.840 - 1.600
R-factor0.1798
Rwork0.178
R-free0.20950
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.065
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]37.8401.630
High resolution limit [Å]1.6001.600
Rmerge0.0620.152
Rmeas0.0870.215
Rpim0.0620.152
Total number of observations447642079
Number of reflections243871214
<I/σ(I)>7.63.8
Completeness [%]99.8
Redundancy1.81.7
CC(1/2)0.9870.912
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.52890.1 M Tris-HCl, pH 8.50, 25% PEG-4000, 8% 2-Methyl-2,4-pentanediol

221051