Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

9EPM

Mpro from SARS-CoV-2 with 4A mutation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-10-06
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.9184
Spacegroup nameC 1 2 1
Unit cell lengths113.670, 53.320, 45.200
Unit cell angles90.00, 101.97, 90.00
Refinement procedure
Resolution48.125 - 1.981
Rwork0.197
R-free0.26630
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.831
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0425)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.1252.080
High resolution limit [Å]1.9801.980
Number of reflections183231210
<I/σ(I)>8.87
Completeness [%]98.6
Redundancy6.3
CC(1/2)0.9670.346
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29320% Polyethylene glycol monomethyl ether 5.000, 200 mM Potassium formate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon