Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

9EPL

Mpro from SARS-CoV-2 with 298Q mutation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-10-06
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9184
Spacegroup nameC 1 2 1
Unit cell lengths114.260, 53.100, 44.630
Unit cell angles90.00, 102.54, 90.00
Refinement procedure
Resolution47.944 - 1.800
Rwork0.148
R-free0.22760
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.015
RMSD bond angle2.107
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0403)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.9501.610
High resolution limit [Å]1.5201.520
Number of reflections362715851
<I/σ(I)>11.70.55
Completeness [%]90.0
Redundancy2.45
CC(1/2)0.9900.343
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29320% PEG 3350, 0.1 mM benzamidine hydrochloride, 200 mM potassium formate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon