8FG6

Design of amyloidogenic peptide traps

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2022-06-13
DetectorDECTRIS EIGER2 X 16M
Wavelength(s)0.97918
Spacegroup nameP 31 2 1
Unit cell lengths64.540, 64.540, 112.618
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution55.890 - 2.300
R-factor0.21463
Rwork0.212
R-free0.25952
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.012
RMSD bond angle1.628
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]55.8902.380
High resolution limit [Å]2.3002.300
Rmerge0.1180.962
Rpim0.0330.261
Number of reflections125541224
<I/σ(I)>12.972.87
Completeness [%]99.5
Redundancy13.614.5
CC(1/2)0.9960.990
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.82930.1 M Tris pH 7.8, poly-gamma-glutamic acid, 15% PEG 4000