7VST
Phosphoglucomutase_tlr1976
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL18U1 |
Synchrotron site | SSRF |
Beamline | BL18U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-11-02 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.97915 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 155.692, 155.724, 177.427 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.730 - 2.740 |
R-factor | 0.2002 |
Rwork | 0.199 |
R-free | 0.22380 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1kfq |
Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.730 | 2.820 |
High resolution limit [Å] | 2.740 | 2.740 |
Rmerge | 0.062 | 0.955 |
Number of reflections | 56641 | 4606 |
<I/σ(I)> | 17.4 | |
Completeness [%] | 99.7 | |
Redundancy | 6.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | NaCl |