Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7P4B

HLA-E*01:03 in complex with IL9

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2017-07-20
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.9763
Spacegroup nameC 1 2 1
Unit cell lengths244.562, 48.529, 153.161
Unit cell angles90.00, 116.95, 90.00
Refinement procedure
Resolution75.180 - 1.720
R-factor0.2026
Rwork0.201
R-free0.23710
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6gh1
RMSD bond length0.003
RMSD bond angle0.616
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareMOLREP
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]114.0301.750
High resolution limit [Å]1.7201.720
Number of reflections1713978228
<I/σ(I)>8.1
Completeness [%]99.8
Redundancy6.5
CC(1/2)1.0000.560
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293.52.2 M AS 0.1 M MES pH 5.8

221051

PDB entries from 2024-06-12

PDB statisticsPDBj update infoContact PDBjnumon