Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6X7L

LnmK in complex with 2-nitronate-propionyl-CoA

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]80
Detector technologyIMAGE PLATE
Collection date2016-02-17
DetectorMAR scanner 300 mm plate
Wavelength(s)0.97872
Spacegroup nameP 61 2 2
Unit cell lengths60.975, 60.975, 310.859
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution29.940 - 1.770
R-factor0.1657
Rwork0.164
R-free0.19900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4hzo
RMSD bond length0.012
RMSD bond angle1.844
Data scaling softwareHKL-2000
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0258)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0001.830
High resolution limit [Å]1.7701.770
Rmerge0.0790.257
Rmeas0.081
Rpim0.018
Total number of observations709330
Number of reflections347833310
<I/σ(I)>11.114.583
Completeness [%]99.798.3
Redundancy20.420.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7298150 mM lithium sulfate, 100 mM Bis-Tris pH 7.0, 28% PEG 3350

221051

PDB entries from 2024-06-12

PDB statisticsPDBj update infoContact PDBjnumon