6PYO
Calcium Activated Chloride Channel Regulator 1 (CLCA1) VWA Domain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 4.2.2 |
Synchrotron site | ALS |
Beamline | 4.2.2 |
Temperature [K] | 100 |
Detector technology | CMOS |
Collection date | 2017-08-09 |
Detector | RDI CMOS_8M |
Wavelength(s) | 1.000 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 104.860, 71.780, 74.840 |
Unit cell angles | 90.00, 109.76, 90.00 |
Refinement procedure
Resolution | 58.050 - 2.000 |
R-factor | 0.1987 |
Rwork | 0.197 |
R-free | 0.22510 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4rck |
RMSD bond length | 0.011 |
RMSD bond angle | 1.181 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.15.2_3472) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 58.050 | 2.050 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.090 | 1.814 |
Rmeas | 0.098 | 2.085 |
Rpim | 0.038 | 0.996 |
Number of reflections | 34813 | 2257 |
<I/σ(I)> | 10.7 | 0.6 |
Completeness [%] | 98.3 | 86.3 |
Redundancy | 6.4 | 4.2 |
CC(1/2) | 0.998 | 0.507 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 290 | 0.2 M HEPES pH 7.5, 0.1 M CaCl2, 28% PEG 400 |