Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6H85

MamM CTD H264E-E289H - Cadmium form

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2017-07-27
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.9795
Spacegroup nameC 2 2 21
Unit cell lengths36.231, 94.249, 53.096
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.120 - 2.000
R-factor0.18932
Rwork0.186
R-free0.22012
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3w5x
RMSD bond length0.013
RMSD bond angle1.606
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0171)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]53.1002.050
High resolution limit [Å]2.0002.000
Rmerge0.051
Number of reflections6470
<I/σ(I)>29.18.9
Completeness [%]99.695.1
Redundancy12.410.2
CC(1/2)0.9990.993
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.2M AmSu, 0.1M BIS-TRIS pH=5.5, 25% PEG 3350, 1.7mM CdCl2

221051

PDB entries from 2024-06-12

PDB statisticsPDBj update infoContact PDBjnumon