6EQ2
MTH1 in complex with fragment 6
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-02-08 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 60.406, 66.314, 36.138 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 44.656 - 1.802 |
R-factor | 0.1716 |
Rwork | 0.170 |
R-free | 0.20900 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 0.919 |
Data reduction software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.910 |
High resolution limit [Å] | 1.800 | 1.800 |
Rmeas | 0.035 | 0.800 |
Number of reflections | 24898 | 3917 |
<I/σ(I)> | 21.26 | 10.53 |
Completeness [%] | 96.0 | 94.2 |
Redundancy | 2.28 | 2.16 |
CC(1/2) | 0.999 | 0.991 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.5 | 293 | 23 % PEG3350, 0.2 M LI2SO4, 0.1 M SODIUM ACETATE PH 4.5 |