Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6CMJ

Human CAMKK2 with GSK650393

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyCCD
Collection date2007-08-08
DetectorADSC QUANTUM 210
Wavelength(s)1.000
Spacegroup nameP 31 2 1
Unit cell lengths89.841, 89.841, 181.385
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution27.970 - 2.400
R-factor0.1845
Rwork0.182
R-free0.21920
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.521
Data reduction softwareDENZO
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0189)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0002.480
High resolution limit [Å]2.3905.1502.390
Rmerge0.0610.0350.311
Number of reflections3320836522484
<I/σ(I)>12.6
Completeness [%]96.298.873.2
Redundancy8.18.47.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52984 M sodium formate, 3% PEG8000, 20 mM ammonium sulfate

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon